Cleaning and maintaining hotel hair dryers – filter, hose, holder: how hotel dryers last longer

In short: A hotel hair dryer runs every day, often for many different guests. The most common reason for weaker performance is a clogged filter at the air inlet. On hose units, the hose with handle wears first. A quick look during room cleaning, a filter schedule and regular electrical testing keep the device safe and make it last much longer.

Why the filter matters

A hair dryer draws in room air, and with it hair, lint and dust. The filter at the air inlet keeps them away from the motor. If it clogs, less air gets through, the inside gets hotter and the overheating protection switches off. To the guest this looks like a broken dryer.

In the instructions for the MatrixCare range, Valera states that the air inlet filter must always be kept free of dirt and recommends regular cleaning with a brush. Valera does not give a fixed interval. Which devices have a removable filter is stated in the manufacturer’s information:

DeviceFilter according to the manufacturerSpare
Valera MatrixCare (hand-held)metal filter, removed by turning anticlockwiseFilter and cleaning kit 501CKB
Valera Excel 1600 Shaverremovablenot sold separately
Valera Silent Jet PROTECT 2000removable metal filternot sold separately
elchim 7 Stars Classicremovablenot sold separately
Aliseo Black Mambo, Tango, Carbonic, Polarfoxspare filter availableSpare filter 500342
Valera Hotello, Action Super Plusnot stated in our documents–

Cleaning schedule for housekeeping

The intervals below are our recommendation for hotel operation, not a manufacturer requirement. In pool and gym changing rooms, where many guests dry their hair, shorten them.

WhenWhatWho
at every room cleaningdryer hangs in the holder and is off; cable or hose without kinks or cracks; holder firmly fixed; wipe the housinghousekeeping
as soon as lint is visible in the grille or the airflow weakensremove the filter, clean it with a brush, refit it dryhousekeeping or maintenance
once a month (recommendation)short function test: switches on when lifted and off when hung up; the Hotello switches off by itself after 8 minutesmaintenance
at the interval set for your propertyelectrical testing according to national rulesqualified electrician

Only clean the switched-off, cooled-down device and never get water into the air inlet. A damaged cable, a torn hose or a loose holder mean: take the device out of service immediately and hang up a replacement.

Hose, coiled cable and holder

  • Hose with handle: on wall-mounted hose units such as the Valera Hotello, the hose is pulled out and moved at every use, so it is the part with the most wear. Valera supplies hose and handle as one spare part; wall mounting and fixed connection remain untouched when it is replaced.
  • Coiled cable: hand-held dryers with a holder hang on a coiled cable. A kink or a chafed spot is noticed early during room cleaning. Do not repair the cable yourself – replace the device or have it checked by an electrician.
  • Holder and safety switch: according to the manufacturer, Valera holders of type 044 switch the dryer off automatically as soon as it is hung up; the 038A holders of the Action series have an on/off safety switch. If a dryer keeps running in the holder, take it out of service immediately.

How holders are mounted correctly is explained in the guide Mounting a wall hair dryer in the hotel bathroom.

Electrical testing

Electrical equipment in commercial premises is tested at regular intervals. The rules are national: in Germany, for example, DGUV Regulation 3, in Austria the Electrical Protection Ordinance (ESV 2012), in the Netherlands inspections usually follow NEN 3140, in Belgium the RGIE/AREI, in France the Labour Code. Your electrician knows the intervals that apply to your property.

What residual current protection does is explained in the guide Hair dryers with RCD; standards and operator duties are covered under Hotel hair dryer safety.

Keeping spare parts in stock

If you run many rooms, keep the parts with the highest wear in stock. A spare part costs a fraction of a new device.

Spare partforManufacturer no.
Replacement hose with handle, whiteValera HotelloHHW
Replacement hose with handle, black/silverValera HotelloHHBS
Replacement hose with handle, blackValera HotelloHHBB
Filter and cleaning kitValera MatrixCare501CKB
Spare filterAliseo Black Mambo, Tango, Carbonic, Polarfox500342

We are happy to tell you which hose fits your Hotello model – just send us the model number of your device. You will find all devices under Hotel hair dryers; for several rooms there is the Hotel projects page.

Frequently asked questions about caring for hotel hair dryers

Why is the hotel hair dryer suddenly blowing more weakly?

Usually the filter at the air inlet is clogged. Less air gets through, the device gets hotter and may switch off via the overheating protection. Remove the filter and clean it with a brush.

How often should the filter of a hotel hair dryer be cleaned?

Valera does not give a fixed interval. We recommend cleaning it as soon as lint is visible in the grille or the airflow weakens – in changing rooms and gyms much more often than in guest rooms.

Does an electrician have to replace the hose of a Hotello?

Hose and handle are one spare part; wall mounting and fixed connection remain untouched when it is replaced.

How often must a hotel hair dryer be electrically tested?

That depends on national rules and on the risk assessment for your property. Your electrician sets the interval.

The dryer keeps running in the holder – what should I do?

Take it out of service immediately. Valera holders of type 044 switch the dryer off when it is hung up; if that no longer works, the safety switch is faulty and the device must be replaced or checked.